Test kit for the determination of the acid capacity up to pH 4,3; Ks4,3 of all natural and industrial water samples via titration with a liquid titration agent and a pipette with accurate mmol/l calibrations. Description Complete with measuring tube, pipette...
UV medium-pressure systems for water disinfection and the decomposition of organically bound chlorine (chloramines) in swimming pool water. The cost-effective UV-C disinfection is excellently suited for swimming pool water, swimming pool attractions, fountains and...
Contains: 2 x Sight glass windows 30×33 x Flat gasket 24×2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x Pump head, complete2 x Hose adapter 1 x brushes set
Conversion kit for 100 ml bottle For inserting 100 ml bottles instead of 500 ml bottles Technical data: 100 ml bottle insertion for screw top with suction pipe for 100 ml bottles screw top GL32
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process...
High quality pH buffer solution for calibration of your pH electrodes Our 250 ml bottle is characterized by a special hygienic closure, which protects the pH buffer solution from contamination. To provide the required buffer, simply squeeze the bottle together...
Cleaning reagent in 500ml-bottle for Testomat 2000® Self clean Testomat 2000® self clean is a special version of Testomat 2000® with an additional dosing pump for cleaning or disinfecting agents after an analysis. It can be used to remove possible pollution of...
The calibration box is used for the calibration of Modbus sensors. The wires from the sensors are connected to the terminal block on the front of the box and the Box is connected to a computer via a USB interface.Advantages:Simple and safe...
The Testomat® LAB Monochloramine NH2CL and the Testomat® LAB Monochloramine NH2CL-R are online analyzer that photometrically measures the content of monochloramine in process water. The instruments are used for continuous monitoring of process...
The Titromat® KH is used for the automatic determination and monitoring of the carbonate hardness at high hardness measuring ranges.The Titromat®-Geräte KH, M1, M2 und TH are based on the technology, the performance profile and technical basic data of the Testomat...
500 ml bottle original Testomat® 808/BOB indicator 300 for measuring residual hardness. Limit value: 0,02°dH residual hardness 0.0356 °fH 0.356 ppm CaCO3 0.00356 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3...
This electrode is suitable for pool, groundwater and drinking water.Platinum – for standard applications in the pool and environmental sector as well as for normal or high temperature resistanceGold – used in connection with chlorine electrolysis and for...
The Testomat 2000® DUO is suitable for monitoring water hardness, carbonate hardness, p-value or minus m-value of water treatment, water blending and drinking water systems.Performance profile: Monitoring of 2 measuring points with different indicator types, eg....
The cleaning brush sets are equipped with a sun head so that you can clean the measuring chamber faster and more thoroughly. In addition, the brushes absorb the dirt better thanks to their dense bristles.[#dspacer#][#dspacer#]Consist:1x #895218 cleaning brush Ø 6mm1x...
Exclusively for all FashionCare businesses HyMo-Box surface check – easy handling – reliable result! Our HyMo-Box “FashionCare” gives all FashionCare businesses a simple and reliable way to check their hygiene management. “HyMo”...
Original Testomat 2000® Bromine reagent set The original 500 ml bottles can be used immediately for Testomat 2000® Br. Monitoring the content of bromine (Br2) in the range of 0 – 5.6 mg/l (ppm).
Proposed use: for the regeneration of water softeners Composition: evaporated salt (min. 99.9% NaCl) Dimensions / weight of tablet: ø25mm / 14g Moisture content: < 0.08 Filling weight: 10kg per sack Type of packaging: PE film Storage description: store dry...
The 500 ml-bottles of original Titromat® TC 2020 Reagent B can be used immediately in the Titromat M2 without cumbersome filling and refilling. Measuring range: Carbonate hardness: 0.89 – 35.8 ppm CaC03 (resolution: 0.89 ppm CaC03) 0.09 – 3.6 °f...
There is a separate service set especially for Testomat® LAB TH, which contains important spare parts. The service set includes the following spare parts: 1 T2000 gasket kit 2 sight glasses 30×3 1 flow regulator core 3 measuring chamber plugs 1 filter...
Manufacturer Part No. 3999960127 LAQUAtwin EC-33: The world’s first pocket-sized conductivity meter Your mobile laboratory – for use on site: Ideal for water quality tests in aquariums, food and many other applications. HORIBA’s unique compact meter...
This electrode is suitable for use in plants and crops monitoring. It is a refillable laboratory electrode for standard applications and a simple diaphragm.
The LAB2B is a corona discharge type ozone generator with variable ozone output up to 10 g/h ozone in oxygen and 4 g/h ozone using dried air. The air-cooled ozone generator is enclosed in an compact desktop housing for bench use. ApplicationsResearch and...
MB A6K4 is a high capacity mixed bed ion exchange resin consisting of a mixture of strongly basic anion resin and a strongly acidic cation resin for direct water purification.The conductivity is about 0.06 µm/cm.Suitable for use in non-regenerable cartridges, high...
Refill pack: One set of reagents for Testoval® Nitrite for the rapid manual analysis of nitrite content in water in the concentration range 0-1 mg/l N02-.1 set reagents for approx. 100 analysesMeasuring time: approx. 15 minutes ...
Thank you for your interest in our smart and customizable Horiba WQ-300 series instruments.The high-quality digital multi-parameter handheld meters with their generous color LCD display with LED backlight (7 cm x 5.2 cm) are ideally suited for use in the field under...
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The storage solution matching the tester in the 25 ml sachet and the 70ml 475mV redox solution finds...
Spare part bottle connection/suction device: Insert for the screw cap with suction tube for 500ml Testomat 2000® / Testomat ECO® / Testomat / Titromat indicator bottles.
Manufacturer Part No. 3999960123 LAQUAtwin PH-22: The world’s first pocket-sized PH meter Your mobile laboratory – for use on site: Ideal for water quality testing in aquatic, drinking and process water and many other applications. HORIBA’s unique...
The Testomat® LAB TH devices determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and...
Our HyMo-Box “Sterilisation Check” enables you to carry out microbiological validation and routine checks of your steam sterilisers in accordance with the DIN EN ISO 17665 standard and the European Pharmacopoeia*. With the help of the bioindicators from...
cleaneroo maintenance cleaner (blue)No fragrances and dyes, no preservatives, no alcohol Vegan and not tested on animals Completely non-toxic for humans, animals and nature Very productive Anti-allergic Streak-free in half the time – no need to re-polish For all...
Module for manufacturer-independent integration of pH, ORP and conductivity standard sensors (PT1000 based), which do not have an integrated signal converter on site. Integration of existing/existing sensors into the NeoTecMaster® concept via...
The Testomat ECO® C determines the carbonate hardness fully automatically by means of titration. In addition to monitoring and controlling the water quality of water treatment plants, the device is particularly suitable for determining the acid quality in swimming...
Titration kit for the determination of water hardness via complexometric titration 1 drop corresponds to 0.1 degree of German hardness Analyses: approx. 30 (at an average hardness of 1 °dH)
Typical areas of applicationindustrial and municipal, general water and waste water engineeringProcess measurements, electroplating, final inspections, neutralisation plantsdrinking and well water, boiler feed waterlightly contaminated waste waterDouble-chamber design...
Our portable multi-parameter measuring device with innovative high-resolution colour display is suitable for working in all conditions and offers you an integrated user-friendly guide in the form of the set-up and calibration mode. This allows the user to easily and...
Manufacturer Part No. 3999960125 LAQUAtwin EC-11: The world’s first pocket-sized conductivity meter Your mobile laboratory – for use on site: Ideal for water quality tests in aquariums, food, beekeeping (honey) and many other applications HORIBA’s...
When it comes to the hygienic safety of the laundry you process, our HyMo-Box “Professional Laundry Check” enables you to check the disinfecting washing processes you use under practical conditions. By using bioindicators, you ensure optimal hygienic...
– 1 side connected to solenoid valve connector without seal (“Plug and Play”, as plug only has to be plugged onto measuring cell)- 1 side labelled cable with wire end ferruleswhite: PT100brown: PT100yellow: Measuring cell SL green: Measuring...
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The 25ml sachet or 70ml bottle solutions matching the tester can be accommodated in the foam blank....
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen. Inhalt: 5 m Kunststoffrohr PE 6/4×1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10...
In the case of quantitative evaluation, the report is mandatory. It contains the examination number, the sampling points, the results and the examination date.
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The 25ml sachet or 70ml bottle solutions matching the tester can be accommodated in the foam blank....
2-electrode principleproven versions for industrial use measuring ranges 0 … 1 mS/cm (K = 0.1) or 0.01 … 15 mS/cm (K = 1.0) temperature range up to 55 °C, maximum pressure up to 6 bar at 25 °C JUMO ecoLine CR-PVC conductive 2-electrode...
Umrüstsatz für den Wasserzulauf zum Anschluss eines Gewebeschlauches, geeignet für Testomat 2000®-, Testomat ECO®- und Titromat®-Geräte. Inhalt: Schnellverschlussstecker 1/4″ Schnellverschlusskupplung 1/4″ auf Schlauch di=6 mm Verriegelung auf der...
The practical premium analysis case boiler house contains a complete hand-held laboratory for checking the feed water quality. The professional, combined multi parameter conductivity and pH measuring instrument has two replaceable probes. ...
In this adapter set are all parts included, that you need to install a Testomat® 808. Connection set consisting of: plastic hose 6/4 x 1.5 m length reduction 10 t0 6 mm shutoff 3/8″ to 6 mm
Measuring chamber with double glazing for Testomat® 808 complete (1-4 bar), tested.The measuring chamber with double glazing can be used in the event of strong temperature differences between air and test water. Problems caused by steaming up in a humid environment...
Pocket-size conductivity/temp. Meter with replaceable electrode The Basic conductivity/temp. pocket tester is a waterproof, handy and accurate meter for fast as well as accurate measurement of conductivity and temperature. This new waterproof Pocket-size...
The modular pH measuring package consists of a 3 m connection cable, a Modbus head transmitter, the sensor holder and the flat-head pH electrode. Due to the design of the sensor assembly, only the pH electrode needs to be replaced. All other components of this system...
The modular water treatment system was specially developed for the outpatient care sector. While the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the the quantities required in different outpatient centers, as well...
Titration kit for the determination of carbonate hardness via complexometric titration 1 drop corresponds to 1 carbonate hardnessAnalyses: approx. 30 (at an average hardness of 10 °KH) This product is available in following versions: 1 pcs.50...
The 500 ml-bottles original Testomat 2000® Reagenz CrVI 2100 B can be used immediately in the Testomat 2000® CrVI without cumbersome filling and refilling. Measuring ranges: Chromate: 0 – 1.0 mg/l (Resolution: 0.01 mg/l) 1 – 2 .0 mg/l...
Refill pack of DUROVAL® TI titration solution for measuring water hardness across all hardness ranges via complexometric titration. Content: bottle with 25 ml DUROVAL® TI.
The cost-effective UV-C disinfection is excellently suited for swimming pool water, swimming pool attractions, fountains and pond systems. UV treatment does not introduce any unwanted by-products into the water that could lead to possible side effects such as skin or...
DUROVAL® TF is an industrial test kit for the determination of water hardness across all hardness ranges via complexometric titration with a liquid titration agent and a pipette, accurately calibrated in hardness units. Especially recommendable as initial...
Manufacturer Part No. 3200689159 LAQUAtwin NA-11 : The world’s first pocket-sized sodium ion analyser. Your mobile laboratory – for use on site: Ideal for water quality testing in agriculture, plant breeding and other applications. HORIBA’s unique...
Module for manufacturer-independent integration of pH, ORP and conductivity standard sensors (PT1000 based), which do not have an integrated signal converter on site. Integration of existing/existing sensors into the NeoTecMaster® concept via Modbus signal.Advantages:...
The conductivity measuring package consists of a 3 meter connection cable, a Modbus head transmitter, and the conductivity sensor. Due to the design of the sensor assembly, only the sensor needs to be replaced, when it should be worn out . All other components of this...
Solenoid-operated dosing pumps with horizontal mounting, cost-effective and particularly reliable. K pumps are designed for universal use and various industries. The K series includes an MF version with multifunction software and an LPV version for viscous liquids....
The Testomat 2000® Antox is a special version of the Testomat 2000® with an additional pump for dosing a reducing agent. By adding this reducing agent in the already filled measuring chamber, the disturbance of oxidizing agents is eliminated. The...
The Gasmaster III system is a stationary measuring instrument for continuous ozone measurement in the vicinity of ozone generators, residual ozone destroyers and ozone treatment plants.The measuring system consists of:Gasmaster evaluation unit in wall-mounted housing...
Replacement color comparator without cuvette, for fast manual analysis of the pH value in water in the range pH 8 to 12.The individual values 8 mg/l, 8.5 mg/l, 9 mg/l, 10 mg/l, 11 mg/l and 12 mg/l can be read by optical color comparison. Only the color comparator for...
Refill pack: One set of reagents Testoval® Sulfite Measurement parameters: Sulfite Measuring range: 0-20 mg/l SO32 Application: Colour comparison kit for the concentration range 0-20 mg/l SO32-. 1 set reagents (1xA,...
The Testomat® 808 is a compact analyzer for the online measurement of water hardness according to the principle of ” limit value monitoring by color change “. The Testomat® style=”letter-spacing: 0px;”> 808 is a combination of the...
The JUMO “Heavy Duty” pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and...
Service set contains:2 x sight glasses 30 x 33 x flat gasket 24 x 21 x insert for screw cap & suction tube 100 ml bottle1 x insert for screw cap & suction tube 500 ml bottle1 x double pump head conversion kit1 x gear motor2 x Hose connector1 x Cleaning brush...
Pocket-size Conductivity/TDS/Temperature Meter with replaceable electrode This new waterproof Basic conductivity-high/TDS/temp. pocket tester for high measuring range include features such as a replaceable probe, temperature in °C or °F, automatic...
Thank you for your interest in our smart and customizable Horiba WQ-300 series instruments.The high-quality digital multi-parameter handheld meters with their generous color LCD display with LED backlight (7 cm x 5.2 cm) are ideally suited for use in the field under...
Replacement color comparator without cuvette for rapid manual analysis of the nitrite content in water in the concentration range 0-1 mg/l N02.The individual values 0.05 mg/l, 0.1 mg/l, 0.2 mg/l, 0.3 mg/l, 0.5 mg/l and 1 mg/l can be read by optical color comparison....
Did you know that, according to the World Health Organisation (WHO), up to 80 percent of all infectious diseases are transmitted via the hands? Consistent cleaning and disinfection of relevant surfaces is therefore one of the most important measures to prevent the...
Our portable multi-parameter measuring device with innovative high-resolution colour display is suitable for working in all conditions and offers you an integrated user-friendly guide in the form of the set-up and calibration mode. This allows the user to easily and...
Plug-in card for a voltage interface, suitable for Testomat 2000® and Titromat® instruments. Technical Data output voltage: 0/2-10V galvanic isolation:
The Neomeris flush panel was developed for simple conductivity-controlled flushing processes in the cooling tower area. The control of the electric motor valve for the blowdown is carried out using a conductivity measuring cell of the type NeoTec Select. The...
Color comparison kit for the rapid manual analysis of silicate content in water in the concentration range 0-10 mg/l SiO2. The individual values … 0.25 mg/l 0.5 mg/l 1 mg/l 2.5 mg/l 5 mg/l 10 mg/l … can be read by visual color comparison. ...
BlackLine pH/ORP electrodes with plastic shaft and fixed protection basket.Selected version: Without temperature sensor (not available for this series, only for Jumo tecLine and tecLine HD series)Screw head S8 Pg13.5 Glass fibre diaphragm Plastic shaft...
Kit for the determination of chloride contents in water. Description Complete with all accessories and reagents. Analyses: approx. 200 Measuring time approx. 2 minutes Pipette: calibrated from 0-300 mg/l CI- Accuracy: 10 mg/l CI-...
Refill pack: Reagents for the rapid manual analysis of ammonium content in water in the concentration range 0-10 mg/l NH4+.1 set reagents (1xA, 1xB, 1xC)for approx. 70 analysesMeasuring time: approx. 4 minutes
Complete colour comparison kit TESTOVAL Iron for rapid manual analysis of the iron content in water in the concentration range 0 – 1 mg/l Fe Individual values … 0.05 mg/l 0.1 mg/l 0.25 mg/l 0.5 mg/l 0.75 mg/l 1 mg/l … can be read by visual...
Dear customers, please note that the calibration of the Testomat® 808 SiO2 can only be carried out with silicate-free water. Therefore, please use the silicate filter cartridge specially developed for this purpose when replacing the double pump head (art. no....
Conductivity meter for conductivity monitoring Our innovative conductivity meter was developed specifically for monitoring the conductivity of aqueous solutions. With a measuring range of 0 to 5 µS/cm, our device is particularly suitable for monitoring low...
Ein hoher Kohlensäure-Gehalt im Probenwasser verfälscht die Messergebnisse. Setzen Sie darum den Kleinrieseler R vor dem Testomat® ein, um den CO2-Gehalt im Probenwasser zu reduzieren. Technische Daten Max. 12 l/h Wasserdurchlauf bei Reduzierung der freien...
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display...
ID=1.6mm complete2x screws M3x40, M3x501x shaft extension1x spacer plate1x double pump head with hoses1x hose extension1x 1.5 mm Allen keyImportant:After replacement, the pump must be recalibrated in Testomat® 808 SiO2. The adjustment is available from firmware...
Refill pack: One set of reagents for TESTOVAL® PH-VALUE 5.5-8 KIT for the rapid manual analysis of pH-value of water range pH 5.5 – 8. 1 set reagents for approx. 250 analysesMeasuring time: 1 minute
Cooler consists of Titanium steel 1.4571 for automatic sampling to 200°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm...
Insert with screw cap and suction tube Tube olive 3.5mm for 500 ml bottle for Testomat® 808 SiO2, Testomat 2000® PO4,Testomat 2000® Polymer as well as Testomat® LAB CL.
Testomat 2000® Antox-solution 2 x 100 ml bottle for Testomat 2000® Antox. Concentrations of oxidising agents, such as chlorine, chlorine dioxide or ozone, above TVO-approved (German drinking water ordinance) limit values have a detrimental effect on the dye...
The 500 ml-bottles of original Testomat 2000® Reagenz SO3 A can be used immediately in the Testomat 2000®® SO3 without cumbersome filling and refilling. Measuring range: Sulphite SO3: 0.0 – 20.0 mg/l
100 ml bottle original Testomat® 808/BOB indicator 310 for measuring residual hardness. Limit value: 1°dH residual hardness 1.78 °fH 17.8 ppm CaCO3 0.178 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces....
Suction lance for extracting a medium directly from a supply container (canister/IBC/CNT tank/barrel)Foot valve with pre-filter and non-return valve. The level switch generates a digital empty signal. Venting nipple 4mm for return of venting hose from dosing pump or...
Repair and maintenance case T2000/EVO TH/ECO for professionals Content: 15 x plugs for measuring chamber5 x filter screens for feed 19.5dx252 x springs for feed5 x flow regulator cores, complete10 x O-rings 10.82×1.7810 x O-rings 20×25 x O-rings...
The Testomat® LAB TH and Testomat® LAB TH-R (Remote)determine the water hardness (residual total hardness) fully automatically by titration. The instrument is suitable for controlling the water quality of water treatment plants, drinking water...
This electrode is suitable for swimming pools, water treatment, drinking water, boiler feed water and municipal sewage treatment plants. Platium – ElectrodeGold – Electrode
The Testomat 2000® PO4 process photometer is an online analyzer for monitoring the content of ortho – phosphate in the range 0 to 10.0 mg/l (ppm) by using the photometric analysis principle.Performance profile: Analysis via automatic dosing of two reagents The...
Find everything you need for the water analysis in the boiler house in this Heyl analysis set: We offer individual versions, if you want a different composition. Content of Analysis Case Boiler House:Titration sets: 1 Duroval A, 1 Duroval B, 1 Duroval...
Titration kit for the determination of water hardness via complexometric titration 1 drop corresponds to 1 degree of German hardnessAnalyses: approx. 30 (at an average hardness of 10 °dH) This product is available in following versions: 1 pcs. (ready...
The Porta Sens III is a mobile gas measuring device for carrying out regular leak checks in gas storage areas, near process plants, pipelines or in working areas. Features:Latest Smart SensorsInternal sample pump and external sample suctionNiMH D-cell battery or...
The Testomat 2000® CAL with additional calibration function automatically determines water hardness, carbonate hardness, the p-value or the minus m-value via titration. It is ideal for monitoring the water quality of water treatment, water blending and...
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The 25ml sachet or 70ml bottle solutions matching the tester can be accommodated in the foam blank....
The Testomat 2000® Fe process photometer is an online analyzer for monitoring the dissolved iron (II) + (III) content in the range of 0 to 1.0 mg / l (ppm) using the photometric analysis principle.Performance profile: Analysis via automatic dosing of two...
Note: The system shown, consisting of two cabinets, is the fully equipped version of our system. The basic price is therefore supplemented by the selected options.The modular water treatment system was specially developed for the outpatient care sector. While the...
Reagent A – 2 x 500 ml (CL2250A)Reagent B – 1 x 400 ml (CL2250B)(the reagent sets are designed for a uniform consumption of the reagents. Therefore, the capacities of the single reagent bottles are not equal)
The data logger with USB connection can be used in Testomat® 808 devices. It provides a protocol of the readings and notifications of the Testomat® 808 using the 20mA current loop. Data access is performed via the built-in USB port. Technical Data Monitors...
The 500 ml-bottle of original Titromat® TH 2500 Reagent A can be used immediately in the Titromat TH without cumbersome filling and refilling. Auflösung: 2,5 °dH Measuring range Water hardness: 44.8 – 895 ppm CaC03 (resolution: 44,8 ppm...
LIMIT VALUE TEST KIT Liquid special indicator in dropper bottle for the monitoring of softened water, set for the limit values of 1 and 0.5 °dH (17,9 and 8,9 ppm). Description Complete with measuring tube and stopper Analyses: approx....
Colour comparison kit for the concentration range 0-20 mg/l SO32-. Individual values … 0.5 mg/l 1 mg/l 2.5 mg/l 5 mg/l 10 mg/l 20 mg/l … can be read by visual color comparison. In addition to the two reagents a color comparison device...
Contents: 1 x Screwdriver Torx 10×80-3K1 x screwdriver VDE slot 0,5x3x1001 x water pump pliers, infinitely variable1 x flat round nose pliers VDE L200MM1 x screwdriver Torx 8×60-3K1 x screwdriver Torx 9×60-3K1 x screwdriver VDE slot 0,5x3x100
The housing for holding the master or display unit as well as up to 6 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement...
Contains: 2 x Sight glass windows 30×33 x Flat gasket 24×2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 100 ml bottle1 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x brushes set
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode...
Industrial test kit for the determination of water hardness across all hardness ranges via complexometric titration with a liquid titration agent and a pipette, accurately calibrated in hardness units. Especially recommendable as initial equipment for water...
Color comparison kit for the rapid manual analysis of chloride content in water in the concentration range 0-100 mg/l Cl-. The individual values … 1 mg/l 5 mg/l, 10 mg/l 25 mg/l 50 mg/l 100 mg/l … can be read by visual color comparison. ...
100 ml bottle original Testomat® 808/BOB indicator 300S for measuring residual hardness. Limit value: 0,05° dH residual hardness 0.089 °fH 0.89 ppm CaCO 0.0089 °mmol/l Please notice, that 100 ml. bottles are only available in...
Refill pack: 1 set of TESTOVAL Iron reagents for the concentration range 0-1 mg/l FeThe individual values …0.05 mg/l0.1 mg/l0.25 mg/l0.5 mg/l0.75 mg/l1 mg/l … can be read by optical colour comparison. By diluting the water sample 1:10 with distilled...
The modular water treatment system was specially developed for the outpatient care sector. While the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the the quantities required in different outpatient centers, as well...
The motor and pump head have to change after 120 operating hours.You reach this at a analysis interval of 30 minutes after aprox. 2 years.It means, the motor have a service life of under one year at a interval of 10 minutes.You can’t change the pump head only,...
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring...
100 ml bottle original Testomat® 808/BOB indicator 330 for measuring residual hardness. Limit value: 3° dH residual hardness 5.34 °fH 53.4 ppm CaCO3 0.534 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2...
Cooler consists of Titanium steel 1.4571 for automatic sampling to 120°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm...
Test kit for the determination of water hardness across all hardness ranges via complexometric titration with a liquid titration agent and a pipette, accurately calibrated in °dH hardness unit. Description Complete with measuring tube, pipette calibrated from...
Ozonia* Membrel MkV ozone generation plant based on the catalytic water electrolysis process; suitable for sterilization and sanitization of ultrapure water in ring piping systems in the pharmaceutical and semiconductor industriesThe plant consists of 1, 2 or 3...
Spare color comparator without cuvette, TESTOVAL Chloride for fast manual analysis of the chloride content in water in the concentration range 0-100 mg/l Cl.The individual values 1 mg/l, 5 mg/l, 10 mg/l, 25 mg/l, 50 mg/l and 100 mg/l can be read by optical color...
100 ml-bottles of original Testomat® 808 SIO2 Reagent Set A+B for monitoring the level of SiO2 in the water. The bottles of original Testomat® 808 SIO2 Reagent can be used immediately in the instrument without cumbersome filling and refilling. Measuring...
The solenoid-operated metering pumps with vertical mounting are easy to install, cost-effective and reliable. Features: Digital system Microprocessor technology Constant mA signal input Volt signal input Batch dosing Operation pause mode Water meter ...
The Testomat® ECO / EVO automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process...
The modular ORP measuring package consists of a 3 m connection cable, a Modbus head transmitter, the sensor holder and the ORP flat-head electrode. Due to the construction of the sensor only the ORP electrode has to be replaced. All other components of this system can...
Manufacturer Part No. 3999960122 LAQUAtwin PH-11: The world’s first pocket-sized PH meter Your mobile laboratory – for use on site: Ideal for water quality testing in aquatic, drinking and process water and many other applications HORIBA’s unique...
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water....
Color comparison kit for the rapid manual analysis of the pH-value in the range pH 6.8 – 8 and chlorine content in water in the concentration range 0 – 1 mg/l free and total chlorine. The individual pH-values … pH 6.8 pH 7.4 pH 8 … and...
Steuerung Softmaster® MMP compact für die vollautomatische Regeneration von Wasserenthärtungsanlagen; geeignet für Zentralsteuerventile oder Pilotverteiler, angesteuert über elektrischen Wechsel- oder Impulsschalter für Einfilter-, Zweifilter-Wechselschaltung; mengen-,...
The Testomat® EVO TH CAL with additional calibration function automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment, drinking water systems, industrial boilers and...
The 500 ml-bottle of original Titromat® TC 2060 Reagent B can be used immediately in the Titromat® KH without cumbersome filling and refilling. resolution: 2 °dH Measuring range: Carbonate hardness: 89,5 – 2685 ppm (resolution: 8,9 ppm) 35,8...
Contents: 1 x 37570 Solenoid valve complete Testomat® 808 2 x 37580 Insert with screw cap and suction tube 100ml bottle 1 x 37859 double pump head Testomat® 808 1 x 31972 SUB-D null modem cable, 9-pin, 2 x socket, 3m ...
Refill pack: One set of reagents for TESTOVAL® PH-CHLORINE DPD for the rapid manual analysis of the pH-value in the range pH 6.8 – 8 and chlorine content in water in the concentration range 0 – 1 mg/l free and total chlorine.1 set reagents...
The Titromat® M1 is used for the automatic determination and monitoring of carbonate hardness at low hardness measuring ranges. Titromat® KH, M1, M2 and TH are based on the instrument technology,the performance features and the basic technical data of Testomat...
The 500 ml-bottles of original Testomat 2000® Reagent SO3 B can be used immediately in the Testomat 2000®® SO3 without cumbersome filling and refilling. Measuring range: Sulphite SO3: 0.0 – 20.0 mg/l
Refill pack: Reagents for the rapid manual analysis of aluminium content in water in the concentration range 0-1,5 mg/l Al.1 set reagents (1xA, 2xB)for approx. 130 analysesMeasuring time: approx. 6 minutes
Our Neomeris conductivity cell with 12mm connection is used for the determination of the electrical conductivity in aqueous solutions. Inside the T-piece is the two-electrode measuring cell without temperature compensation. The installation is easy and fast due...
Refill pack: Reagents for the rapid manual analysis of hexavalent chromium content in water in the concentration range 0-5 mg/l Cr.1 set reagents (1xA, 2xB)for approx. 180 analysesMeasuring time: approx. 3 minutes
This service kit contains all the spare parts for the regular maintenance of Testomat 2000®, Testomat ECO®, Titromat® or Testomat® EVO TH instruments. Content: 1 T2000 gasket kit 2 30×3 sight glass 1 flow regulator cores 3 stoppers for measuring chamber 1...
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special...
The Testomat 2000® ClO2 process photometer is an online analyzer for monitoring the content of chlorine dioxide (ClO2) in the range of 0–4,7 mg/l (ppm)Performance profile: Analysis via automatic dosing of two reagents The analysis result is displayed after a reaction...
Our portable multi-parameter meter with innovative high-resolution colour display is suitable for working in all conditions and offers you an integrated user-friendly guide in the form of the set-up and calibration mode, whereby consultation is required for cooling...
Capacity measurement ion exchanger cartridgeOur Neomeris N-FLASH10 conductivity meter in a T-piece with 3/8 inch connection is a conductivity measuring instrument that is used to monitor the electrical conductivity of water after flowing through the ion exchanger...
TESTOVAL Hydrazine color comparison kit for rapid manual analysis of the hydrazine content in water in the concentration range 0-1 mg/l N2H4.The individual values 0 mg/l, 0.05 mg/l, 0.1 mg/l, 0.25 mg/l, 0.5 mg/l and 1 mg/l can be read by optical color comparison. In...
Test kit for the determination of the carbonate hardness or the m-value (acid capacity up to pH 4,3, Ks4,3) of all natural and industrial water samples via titration with a liquid titration agent and a pipette with accurate °dH and mmol/l calibrations. ...
cleaneroo kitchen cleaner (yellow)Easily removes: fats, nicotine, proteins, caffeine, etc. Gentle on materials Completely non-toxic No fragrances or dyes Also ideal for floors (1:10) Very productive
The Testomat 2000® CLT Self Clean process photometer with additional cleaning function for the measuring chamber is an online analyzer for monitoring the total chlorine content (CLT) in the range of 0-2.5 mg / l (ppm). Switchable to free chlorine in the...
Refill pack: 8 ml bottle DUROVAL® C indicator For the determination of the carbonate hardness or the m-value (acid capacity up to pH 4,3; Ks4,3) of all natural and industrial water samples via titration.
The system consists of:Ozone generator with high voltage / high frequency power supply and ozone generator module with a ceramic dielectric; function and fault indicators: Ozone fault lamp; operating gas fault indicator, variable ozone output control (internal and...
The Titromat® M2 is used for the automatic determination and monitoring of carbonate hardness at low hardness measuring ranges.Titromat® KH, M1, M2 and TH are based on the instrument technology,the performance features and the basic technical data of Testomat 2000®....
A special service set is available for Testomat® LAB CL and Monochloramine, which contains important spare parts, among other things.Contents:1 x gasket set T20002 x sight glasses 30×31 x flow controller core3 x plugs for measuring chamber2 x screw cap with...
pH/ORP electrodes with glass shaftSelected version: without temperature sensor (not available for this series, only for Jumo tecLine and tecLine HD series) Screw head S8 Pg13.5 Ceramic diaphragm Installation length 120mm (standard) Type code...
The data logger, which is inserted into the Testomat 2000® or Titromat® instrument as a plug-in card, saves the measuring results and fault messages on an SD card. Technical Data The data is available in CSV format and can be further processed or...
for the destruction of excess ozone in the process air. – Heating system with thermostat for 400 °C reactor temperature.- Control system with START/STOP and alarm signal temperature- Insensitive to existing catalyst...
The process photometer Testomat 2000® Br2 is an analytical instrument for online monitoring of the content of bromine (Br2) in the measuring range of 0 – 5.6 mg / l (ppm).Performance profile: Analysis via automatic dosing of two reagents The analysis result is...
This electrode is suitable for higher demands on chemical resistance and temperature. They find their area of application in industrial and in general laboratory applications.
Cooler consists of Titanium steel 1.4571 for for manual sampling to 80°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: 8 mm Cold water outlet: ½ Hot water (in- and outlet): 8 mm...
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode...
High quality conductivity calibration solution to calibrate your electrodes Our 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required...
The Testomat® LAB Monochloramine (NH2CL) is an online analyser that photometrically measures the content of monochloramine in process water and is used for continuous monitoring of process quality, for example in cooling circuits. Another area of application is...
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and...
The practical analysis case contains a complete hand-held laboratory for testing the filling water of heating systems according to VDI guideline 2035. The conductivity meter and pH meter are IP65 certified, which means “dust-tight and protected against water...
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK...
Testomat 2000® reagent FE 2005 A in 500 ml bottleMeasuring range: 0 – 1.0 [mg/l]Test substance: dissolved iron (II) and (III) For the analyser T2000® Fe, whose measuring ranges are as follows:Range I: 0 – 0.65 mg/l, resolution: 0.01 mg/l Range...
500 ml-bottles of original Reagent set PO4 2100 A + B can be used immediately in the Testomat 2000®® PO4 without cumbersome filling and refilling. Measuring range: Phosphate PO4: 0.0 – 10.0 mg/l
cleaneroo soft cloth box of 5 – the gentle one The cleaneroo professional wipes are characterised by a very high performance (professional quality). They are very durable and intended for long-term use. The special structure is ideal for cleaning all...
Test kit for the determination of water hardness across all hardness ranges via complexometric titration with a liquid titration agent and a pipette, accurately calibrated in °f hardness unit. Description Complete with measuring tube, pipette...
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring...
Water sterilisation by UV irradiation The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are...
The instrument is used for conductive measurement / control of the electrolytic conductivity, the resistivity or the TDS value. In addition, the JUMO AQUIS 500 CR offers the possibility of displaying the measured conductivity according to a customer-specific table....
Product description: UV lamp 25W / 40W for Cintropur UV2100 / UV4100 flow-through fitting. The 25W / 40W UV lamp is an essential accessory for the Cintorpur UV2100 / UV4100 flow-through fitting, ensuring maximum efficiency and safety when disinfecting water. With its...
LIMIT VALUE TEST KIT Liquid special indicator in dropper bottle for the monitoring of softened water, set for the limit values of 0.1 and 0.05 °dH (1,79 and 0,89 ppm).DescriptionComplete with measuring tube and stopper Analyses: approx. 250Measuring...
Version: Glass shaft UW glassPTFE- ring diaphragmScrew head Pg 13,5 (S8)120mmSalt reservoirType code (shown on the electrode as well):201020/51-18-04-22-120/837 ; Part Nr. 321035
This special service set is designed for the Testomat 2000® Polymer. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head. The service set includes the following spare parts: 1 T2000...
High quality ORP buffer solution for calibration of your ORP electrodesOur 250 ml and 500 ml bottle is characterized by a special hygienic closure, which protects the ORP buffer solution from contamination. To provide the required buffer, simply squeeze the bottle...
Module for manufacturer-independent integration of pH, ORP and conductivity standard sensors (PT1000 based), which do not have an integrated signal converter on site. Integration of existing/existing sensors into the NeoTecMaster® concept via...
cleaneroo microfibre cloth box of 5 – the powerful one streak-free no need to re-polish without fragrances and dyes high-purity product 100% biodegradable
The Testomat 2000® Self clean is a special version of the Testomat 2000® with an additional dosing pump for dosing a a cleaning solution after analysis. It can be used to remove pollution of the measuring chamber and the drain hose. After the set number...
Device Screw cap GL32 – with hole is a spare part for 100ml and 500 ml bottles of Testomat 2000® / Testomat ECO® / Testomat® EVO TH / T808 and Titromat.
pH/ORP electrodes with plastic shaft and clip-on protection basketSelected version:Without temperature sensor (not available for this series, only for Jumo tecLine and tecLine HD series)Screw head S8 Pg13.5Glass silk diaphragmPlastic shaft PEIMounting length 120mm...
The pressure regulator is suitable for all Testomat® devices. It is used for pressures from 0.5 to 10 bar in order to avoid any pressure fluctuations that may occur and to ensure an optimum operating pressure. Kit consisting of: Pressure gauge, rear connection Bracket...
OZONE GENERATORS FOR WATER TREATMENTThe ozone systems are completely piped, connected and ready for operation on the mounting frame. The systems each consist of:Ozone generator with high voltage/high frequency power supply and ozone generator module with a...
Color comparison kit for the rapid manual analysis of hexavalent chromium content in water in the concentration range 0-5 mg/l Cr. The individual values … 0.1 mg/l, 0.25 mg/l 0.5 mg/l 1 mg/l 2.5 mg/l 5 mg/l … can be read by visual color...
Manufacturer Part No. 3999960126 LAQUAtwin EC-22: The world’s first pocket-sized conductivity meter Your mobile laboratory – for use on site: Ideal for water quality tests in aquariums, food and many other applications. HORIBA’s unique compact meter...
Titration solution associated to the test kit for determination of acid capacity up to pH 4.3. Complete withmeasuring tube, dosing pipette (calibrated), special connection plug, 8 ml indicator and 50 ml titration solution.
Data logger, developed for Testomat 2000® and ®Titromat with network connection for remote enquiry and maintenance. Technical DataThe network logger plug-in card for Testomat 2000® is a miniature computer with network connection, webserver, FTP server and...
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial...
Gasket kit T2000 (according to maintenance complexity) TESTOMAT®2000 Spare part requirements for 2-3 years of operation gasket kit T2000 (according to maintenance complexity) Gasket kit T2000 (according to maintenance complexity) contains: 4 x flat...
100 ml bottle original Testomat® 808/BOB indicator for measuring residual hardness. Limit value: 0,1° dH residual hardness 0.178 °fH 1.78 ppm CaCO3 0.0178 °mmol/l Please notice, that 100 ml. bottles are only available in...
Refill pack: DUROVAL® C titration solution for the determination of the carbonate hardness or the m-value (acid capacity up to pH 4,3; Ks4,3) of all natural and industrial water samples via titration.
The Titromat® TH is used for the automatic determination and monitoring of high water hardness in aqueous media.Titromat® KH, M1, M2 and TH are based on the instrument technology,the performance features and the basic technical data of Testomat 2000®.Applications:...
Device for measuring the electrical conductivity of aqueous solutions in conjunction with an integrated two-electrode screw-in measuring cell 3/4 inch without temperature compensation. The devices are selected according to the respective measuring range and are...
A ORP sensor from the NeoTec Select Standard product range with 4 – 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
Color comparison kit for the rapid manual analysis of aluminium content in water in the concentration range 0-1,5 mg/l Al. The individual values … 0 mg/l, 0.1 mg/l 0.2 mg/l 0.5 mg/l 1 mg/l 1,5 mg/l … can be read by visual color comparison. ...
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display...
The Testomat 2000 THCL® process photometer determines the total chlorine content according to the colorimetric analysis principle in the range from 0 to 2.5 mg / l (ppm) and the water hardness by titration.Performance profile: Two independently programmable...
256×64 2,8″, yellowFeatures: When the device is switched on with the display plugged in, the installed software version is displayed during the boot process. This allows you to visually check the current software version after a software...
Contains: 2 x Sight glass windows 30×33 x Flat gasket 24×2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x brushes set
The 500 ml-bottles of original Titromat® TC 2020 Reagent A can be used immediately in the Titromat M2 without cumbersome filling and refilling. Measuring range: Carbonate hardness: 0.89 – 35.8 ppm CaC03 (resolution: 0.89 ppm CaC03) 0.09 –...
In the case of quantitative evaluation, the report is mandatory. It contains the examination number, the sampling points, the results and the examination date.
Color comparison kit for the rapid manual analysis of ammonium content in water in the concentration range 0-10 mg/l NH4+. The individual values … 0.1 mg/l, 0.5 mg/l 1 mg/l 2.5 mg/l 5 mg/l 10 mg/l … can be read by visual color comparison. ...
Content: 2 x 40170 sight glass 30×33 x 33777 flat gasket 24×2 EPDM 602 x 33776 O-Ring 18×2 EPDM3 x 11210 Protection plug to measuring chamber T2000 / ECO / EVO TH / EVO TH CAL1 x 40050 Magnetic stirring core
Titration test kit for the determination of water hardness in raw water (0-30 °dH) and after water treatment (0-2 °dH). Description Measuring range: 0-30 °dH Resolution: 0.5 °dH Measuring range: 0-2 °dH Resolution: 0.025 °dH Complete with all reagents and...
The titration pipette is calibrated from 0 to 300 mg/l SO42-. The measurement range can be expanded to double the concentration via refilling of the titration pipette and to ten-times the concentration by diluting the water sample with distilled water. ...
Test kit for the determination of the water hardness in very soft or softened water samples via titration with a liquid titration agent and a pipette accurately calibrated in hardness units. Complete with …measuring tubecalibrated pipette from 0-2...
In the case of quantitative evaluation, the report is mandatory. It contains the examination number, the sampling points, the results and the examination date.
Color comparison kit for the rapid manual analysis of pH-value of water range pH 5.5 – 8. The individual values … 5.5 mg/l 6 mg/l 6.5 mg/l 7 mg/l 7.5 mg/l 8 mg/l … can be read by visual color comparison. In addition to the reagents a...
In the case of quantitative evaluation, the report is mandatory. It contains the examination number, the sampling points, the results and the examination date.
A pH sensor from the NeoTec Select Standard product range with Modbus modul encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
Waterproof hand-held meter for fast pH/temperature measurement in liquids The Neomeris pH/T Pocket Tester is a waterproof hand-held meter for fast and accurate measurement of pH and temperature in liquids. The temperature sensor and pH electrode can be replaced with a...
100 ml bottle original Testomat® 808/BOB indicator 305 for measuring residual hardness. Limit value: 0,5° dH residual hardness 0.89 °fH 8.9 ppm CaCO3 0.089 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3...
100 ml bottle original Testomat® 808/BOB indicator for measuring residual hardness. Limit value: 0,3° dH residual hardness 0.534 °fH 5.34 ppm CaCO3 0.0534 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3...
The Testomat training course explains the structure, use and maintenance of Testomat devices.You will learn more about the basics of photometric analysis the technical structure and differences between the individual device versions service and maintenance...
The Testomat 2000® CLT process photometer is an online analyzer for monitoring the content of total chlorine (CLT) in the range of 0-2.5 mg / L (ppm); switchable to free chlorine in the same range.Performance profile: Analysis via automatic dosing of three...
This electrode is available as an inexpensive solution as well as with a double diaphragm for higher temperature resistance. It is suitable for general laboratory applications, pH & chlorine in swimming pools & whirlpools.
100 ml bottles original Testomat® Indicator C5 for measuring carbonate hardness / alkalinity with Testomat® C-BOB. limit value:0,5 °dH carbonate hardness Please notice, that 100 ml. bottles are only available in packages of 2 or 3...
Plug-in card for a current interface, suitable for Testomat 2000® and Titromat® instruments. Technical Data output current: 0-20mA or 4-20mA maximum load: 500 Ohm galvanic isolation Usable in following devices: Testomat 2000®, Testomat 2000® CAL,...
Refill pack: bottle with 50 ml liquid titration solution for the determination of water hardness across all hardness ranges via complexometric titration.
Conversion kit for converting the water connection from Testomat® BOB to Testomat® 808. Consisting of:1x Plug nipple G1/4″ DN61x Pipe, PE, D=6 d=4 L=5m1x screw-in connector G1/4″-6
DISINFECTION OF PROCESS AND ULTRAPURE WATER The Neomeris UVprofessional Standard series is used in the food and beverage industry and consists of:Stainless steel reactor (1.4571 DIN EN 10217-7), electropolished inside and out, with TriClamp connections to DIN...
Titration kit for the determination of water hardness via complexometric titration 1 drop corresponds to 1 degree of French hardnessAnalyses: approx. 30 (at an average hardness of 10 °f) This product is available in following versions: 1 pcs.50 pcs....
Color comparison kit for the rapid manual analysis of chlorine content in water in the concentration range 0.5-4 mg/l free and total chlorine. The individual values … 0.5 mg/l 1 mg/l 1.5 mg/l 2 mg/l 3 mg/l 4 mg/l … can be read by visual color...
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The solutions matching the tester in the form of the 25ml sachets or 70ml bottles find space in the...
Test kit for the determination of the carbonate hardness, resp. the m-value (acid capacity up to pH 4.3; KS 4.3) and p-value (acid capacity up to pH 8.2; Ks 8.2) of all natural and industrial water samples via titration with a liquid titration agent and a pipette...
Instrument for measuring the electrical conductivity of aqueous solutions in combination with two-electrode measuring cells without temperature compensation. Designed as measuring instrument with external measuring cell, available with and without potential-free...
Plastic cartridges variantsDK-VE 6 – demineralisation cartridge with hole in the head (capacity max. 900 litres at 300µS)DK-VE 10 – demineralisation cartridge with hole in the head (capacity max. 1,500 litres at 300µS)DK-VE 15 – demineralisation...
Refill pack: One set of reagents for TESTOVAL® PH-VALUE 8-12 Reagents for the rapid manual analysis of pH-value of water range pH 8 – 12.1 set reagentsfor approx. 250 analysesMeasuring time: approx. 1 minute
The Testomat® LAB CL is a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 – 5 mg/l. The instrument is suitable for controlling the water quality of water...
Special indicator in powder form for the rapid colorimetric determination of minimum hardness traces in the range 0-0.1 °dH, 0-1.8 ppm CaCO3 or 0-0.2 °f (French hardness). Complete with measuring tube and spoon. Analyses: approx. 700 Measuring time:...
The modular water treatment system was specially developed for the outpatient care sector. While the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the the quantities required in different outpatient centers, as well...
The process photometer Testomat 2000® CrVI (Standard) is an online analytical measuring instrument for monitoring the content of chromate (CrO42-) in the range of 0 to 2.0 mg/l or chromium VI (CrVI) in the range of 0 to 1.0 mg/l. The device works with a photometric...
This board can be used from serial number 240.000. If you have a device before this serial number, please contact us. We will find the right board for you.
Our portable multi-parameter meter with innovative high-resolution colour display is suitable for working in all conditions and, like our other available Professional meters in the case, offers you an integrated user-friendly guide in the form of the set-up and...
Manufacturer Part No. 3200689161 LAQUAtwin CA-11 : The world’s first pocket-sized calcium ion analyser. Your mobile laboratory – for use on site: Ideal for water quality testing in agriculture, aquariums, food and many other applications. HORIBA’s...
The 500 ml-bottles of original Testomat 2000® Reagenz CIO2 A/B bottles can be used immediately in the Testomat 2000®® CIO2 without cumbersome filling and refilling. Measuring range: chlorine dioxide (ClO2): 0.00 – 4.70 mg/l...
500 ml-bottle of original Testomat® 808 SIO2 Reagent B for monitoring the level of SiO2 in the water. The bottles of original Testomat® 808 SIO2 Reagent can be used immediately in the instrument without cumbersome filling and refilling. Measuring range: Silica...
Proposed use: for the regeneration of water softeners Composition: evaporated salt (min. 99.9% NaCl) Dimensions / weight of tablet: ø25mm / 14g Moisture content: < 0.08 Filling weight: 25kg per sack Type of packaging: PE film Storage description: store dry...
The process photometer Testomat 2000® automatically determines water hardness, carbonate hardness, the p-value or the minus m-value via titration. It is ideal for monitoring the water quality of water treatment, water blending and drinking-water plants....
Thank you for your interest in our smart and customizable Horiba WQ-300 series instruments.The high-quality digital multi-parameter handheld meters with their generous color LCD display with LED backlight (7 cm x 5.2 cm) are ideally suited for use in the field under...
measuring range:0.00 to 14.00 pH0 to 3999 µS/cm 0 to 2000ppm0.0 to 50.0 °C / 32.0 to 122.0 °FResolution:0.01 pH1 uS/cm1 ppm 0.1 °C / 0.1 °FAccuracy (@25°C)0.05 pH2% FS (EC/TDS0.5 °C / ±1 °FTDS factor0.45 to 1.00 (CONV)Temperature CompensationAutomatic, with ß=0.0 to...
The bottles of original Testomat 2000® Chlorine Reagent Set T can be used immediately in the Testomat 2000®® CLT, Testomat 2000® CLT Self Clean or Testomat 2000 THCL® without cumbersome filling and refilling. Content: 2 x 500 ml A, 1 x 400 ml B, 1 x 200...
NeoTec Select Optical Oxygen Sensor with Modbus OutputDurable and reliableStainless steel SS316- housing option for fresh waterTitanium- housing option for salt waterOptical technology allows maintenance-free use for up to 2 years Save time during set-upNo...
The Testomat training course explains the structure, use and maintenance of Testomat devices.You will learn more about the basics of photometric analysis the technical structure and differences between the individual device versions service and maintenance...
Ozone generators CFS for industrial applications and water treatment; water-cooled generator in compact sheet steel housing (IP 42) for oxygen or dried air as operating gas according to the “silent electrical discharge” method.Consisting of the following...
Cooler consists of Titanium steel 1.4571 for manual sampling to 120°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm ...
The bottles of original Testomat® LAB CL chlorine reagent Set F can be used immediately in the Testomat 2000® LAB CL without cumbersome filling and refilling.Contents:2 x 500 ml bottle AF reagent 1 x 400 ml bottle B reagent
DVGW certified unit series for disinfection of drinking water up zo 60 °CFeaturesRadiation chamber made of V4A stainless steel 1.4404 electropolished with sampling tap made of stainless steel, flammable at inlet and outlet Built-in measuring window according to...
Refill pack: Reagents for the rapid manual analysis of chloride content in water.1 set of reagents (3xA, 1xB)for approx. 40 analysesMeasuring time: approx. 3 minutes
A pH sensor from the NeoTec Select Standard product range with 4 – 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
High-quality conductivity meter with a 4-20mA signal output for forwarding the measured value to a higher-level control system, for example. The measurement is temperature compensated and therefore offers you an accurate measurement result. Also here we have the...
Bioindicators for self-monitoring of sterilisers / autoclavesScope of delivery: 3 bioindicators and one transport control (autoclave up to 250l)For these reasons, the inspection and associated validation of autoclaves in healthcare facilities is regulated in various...
100 ml bottle original Testomat® 808/BOB indicator 320 for measuring residual hardness. Limit value: 2° dH residual hardness 3.56 °fH 35.6 ppm CaCO3 0.356 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces....
The Gasmaster III system is a stationary measuring instrument for continuous ozone measurement in the vicinity of ozone generators, residual ozone destroyers and ozone treatment plants.The measuring system consists of:Gasmaster evaluation unit in wall-mounted housing...
The process photometer Testomat 2000® CrVI (High measuring range) is an online analytical measuring instrument for monitoring the content of chromate (CrO42-) in the range of 0 to 11.15 mg/l or chromium VI (CrVI) in the range of 0 to 5.0 mg/l. The device works with a...
The 500 ml-bottles of original Titromat® TC 2010 Reagent B can be used immediately in the Titromat M1 without cumbersome filling and refilling. Measuring range: Carbonate hardness: 0.89 – 17.9 ppm CaC03 0.09 – 1.8 °f (resolution: 2...
Color comparison kit for the rapid manual analysis of phosphate content in water in the concentration range 0-10 mg/l P2O5. The individual values … 0,25 mg/l 0,5 mg/l 1 mg/l 2,5 mg/l 5 mg/l 10 mg/l … can be read by visual color comparison. ...
The JUMO “Heavy Duty” pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and...
Refill pack: 1 set of TESTOVAL Iron reagents for the concentration range 0-10 mg/l FeThe individual values …0.25 mg/l0.5 mg/l1 mg/l2.5 mg/l5 mg/l10 mg/l … can be read by optical colour comparison. Only the reagents are included in the scope of...
Candle filter housing complete for Testomat® 808 / Testomat 2000® / Testomat ECO® candle filter with filter insert for filtering sample water before analysis max. pressure: 4 bar / 58 psi at 40°C (104°F), max. 10 bar / 145 psi at 20°C (68°F) max. temperature:...
The 500 ml-bottles original Testomat 2000® Reagenz CrVI 2100 A can be used immediately in the instrument without cumbersome filling and refilling. Measuring ranges: Chromate: 0 – 1.0 mg/l (Resolution: 0.01 mg/l) 1 – 2 .0 mg/l (Resolution: 0.1 mg/l)...
The modular water treatment system was specially developed for the outpatient care sector. While the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the the quantities required in different outpatient centers, as well...
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of “limit value monitoring with colour change” in the measuring range 0.02 – 5 ° dH (0.4 – 89 ppm). Applications of...
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
TOC REDUCTION IN ULTRAPURE WATER SYSTEMS Stainless steel reactor (1.4571 DIN EN 10217-7; optionally 1.4404) electropolished inside and outside with thread or flange connection to DIN 2576, SUPRASIL quartz immersion tube and UV low-pressure lamp (ozone-forming)....
Brief description The high-quality materials and components of the JUMO tecLine HD electrodes make them particularly suitable for the most demanding applications in process and industrial measurement technology. They are combined combination electrodes (with a...
Ultrasonic flow meters Ultrasonic flow meters work largely independently of the specific properties of the product to be measured, such as pressure, temperature, viscosity or conductivity. Due to these advantages, they can be used in a wide range of applications. A...
Ultrasonic flow meters Ultrasonic flow meters work largely independently of the specific properties of the product to be measured, such as pressure, temperature, viscosity or conductivity. Due to these advantages, they can be used in a wide range of applications. A...
Ultrasonic flow meters Ultrasonic flow meters work largely independently of the specific properties of the product to be measured, such as pressure, temperature, viscosity or conductivity. Due to these advantages, they can be used in a wide range of applications. A...
Ultrasonic flow meters Ultrasonic flow meters work largely independently of the specific properties of the product to be measured, such as pressure, temperature, viscosity or conductivity. Due to these advantages, they can be used in a wide range of applications. A...
Ultrasonic flow meters Ultrasonic flow meters work largely independently of the specific properties of the product to be measured, such as pressure, temperature, viscosity or conductivity. Due to these advantages, they can be used in a wide range of applications. A...
The potentiostatic double gold electrode was developed to measure the free, inorganic chlorine and chlorine dioxide in water. It is used in the treatment of drinking water, bathing water and process water. A fixed potential is set between the measuring and counter...
The EMEC KMS MF series is a versatile dosing pump series that supports various operating modes, including constant, divide, multiply, ppm, perc, mlq, batch, volt, mA and timer. This flexibility enables precise and customisable dosing for different applications. Here...
IP66 waterproof switch 250 V, 20 A Operating voltage 440 Volt Two-position rotary selector switch On and off switch Dustproof For outdoor use IP66 WATERPROOF: The sealing disc is made of high-strength rubber with high corrosion resistance, strong sealing and better...
Service set LOTUS A/MINI 8 / 20 for annual maintenance consisting of: 2 dosing heads VIS pumps acid/sodium chlorite – 4×6 (PVDF+FP+CE)2 PTFE diaphragms type A/I/J, VIS pumps acid/sodium chlorite1 pc. Dosing head VIS pump water dilution – 4×6...
The regular validation of the entire reprocessing process and its repeated implementation in the event of interventions or changes within the reprocessing process is an essential instrument for demonstrating process reliability. In the course of our work as technical...
Whether it is a new project or the expansion of an existing reprocessing facility for medical devices – our experts will accompany and support you during project planning and implementation. The qualified consideration of all relevant project topics, the...
The process analysis represents a comprehensive consideration of all relevant treatment steps and essentially includes A detailed analysis of the water treatment and the associated utilisation of the water qualities producedEvaluation of the equipment technology used...
We accompany you and your team as part of a basic analysis on site. All relevant data on the equipment technology and process water treatment is collected together. Furthermore, the equipment technology and feeding technology used as well as the instruments used are...
Recording your data on equipment technology and process water treatment as a stand-alone inventory analysis in our online matrix enables you to receive qualified professional feedback from our team of experts in a timely manner. With reference to compliance with the...
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display...
JUMO diraVIEW 108 – Digital indicator Version: Standard with factory settings Power supply: AC 110-240 V +10/-15%, 48 to 63 Hz Option 1-4: not assigned Extra code: without 1 analogue input 2 digital inputs (digital input 1 as an alternative to logic...
Room, outdoor and duct resistance thermometers Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct...
JUMO LOGOSCREEN 601 – paperless recorder with touch screen Basic type extension: without software package Option 1-3: not assigned Power supply: AC 110 bis 240 V +10/-15%, 48 bis 63 Hz Extra codes: not assigned Simple operation...
JUMO diraVIEW 108 – Digital indicator Version: Standard with factory settings Power supply: AC 110-240 V +10/-15%, 48 to 63 Hz Option 1-4: not assigned Extra code: without 1 analogue input 2 digital inputs (digital input 1 as an alternative to logic...
JUMO diraVIEW 116 – Digital indicator Version: Standard with factory settings Power supply: AC 110-240 V +10/-15%, 48 to 63 Hz Option 1-4: not assigned Extra code: without 1 analogue input 2 digital inputs (digital input 1 as an alternative to logic...
JUMO diraVIEW 132 – Digital indicator Version: Standard with factory settings Power supply: AC 110-240 V +10/-15%, 48 to 63 Hz Option 1-4: not assigned Extra code: without 1 analogue input 2 digital inputs (digital input 1 as an alternative to logic output) 1...
JUMO meroVIEW – Multifunction digital indicator with PLC function Version: Standard with factory settings Power supply: AC 10 to 240 V +10/-15% / 48 to 63 Hz Extra code: without Option1-6: not assigned 1 analogue input 1...
JUMO miro VIEW – smart digital indicator with limit value monitoring Input: 1 resistance thermometer Pt100, Pt1000 in two-wire circuit, 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (make contact AC 250 V, 5 A)...
JUMO eTRON T100 – electronic thermostat with timer function for mounting on 35 mm top-hat rails Version: Standard with factory settings Input: resistance thermometer Pt100, Pt1000, KTY2X-6 Power supply: AC 230 V +10/-15%, 48 to 63 Hz...
JUMO miro TRON – electronic thermostat with PID two-point controller option Input: 1 resistance thermometer Pt100, Pt1000 in two-wire circuit, 1 digital input Output: 4 relays (NO contact AC 250 V, 2.5 A), resistive load, only for type 701081...
JUMO miro TRON – electronic thermostat with PID two-point controller option Input: 1 resistance thermometer Pt100, Pt1000 in two-wire circuit, 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (NO contact AC 250 V,...
JUMO hydro TRANS S30 – Humidity and temperature transmitter with optional CO2 module in duct version Basic type extension: RH-T Version: StandardMeasuring range: 0 to 100 % RH/-40 to +80 °COutput: 4 to 20 mA/0 to 10 V combined output configuredExtra code:...
JUMO hydro TRANS S20 – Humidity and temperature transmitter with optional wall-mounted CO2 module Basic type extension: RH-T Version: Standard Measuring range: 0 … 100 % rH / -40 … +80°C Output: 4 … 20 mA / 0 … 10 V combi output...
JUMO Midas C08 – OEM – Basic pressure transmitter Input: 0 to 10 bar relative pressure Output: 4 to 20 mA, two-wire Process connection: G 1/4 DIN EN 837 Process connection material: CrNi (stainless steel) Seal material: CrNi...
Contact resistance thermometer with mounting hole Protective fitting aluminium Temperature range from -5 to +105°C (PVC) 1× Pt100 in two-wire circuit Tolerance class according to DIN EN 60751: Class B (standard) Connection cable end: Wire end ferrules to DIN...
Contact resistance thermometer with mounting hole Stainless steel protective fitting Temperature range from -50 to +260°C (PTFE) 1× Pt100 in two-wire circuit Tolerance class according to DIN EN 60751: Class B (standard) Connection...
Contact resistance thermometer with mounting hole Protective fitting stainless stell Temperature range from -50 to +260°C (PTFE) 1× Pt100 in two-wire circuit Tolerance class according to DIN EN 60751: Class B (standard) Connection...
Contact resistance thermometer with mounting hole Stainless steel protective fitting Temperature range from -50 to +260°C (PTFE) 1× Pt100 in two-wire circuit Tolerance class according to DIN EN 60751: Class B (standard) Connection...
Contact resistance thermometer with mounting hole Protective fitting aluminium Temperature range from -50 to +260°C (PTFE) 1× Pt100 in two-wire circuit Tolerance class according to DIN EN 60751: Class B (standard) Connection cable...
Room, outdoor and duct resistance thermometers Typ: 902520/23-474-1003-1/333,(-40..80°C) Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air...
Room, outdoor and duct resistance thermometers Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct...
Room, outdoor and duct resistance thermometers Measuring range from 0 to +40°C (measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 0 to 10 V (only in...
Room, outdoor and duct resistance thermometers Typ: 902520/10-803-1003-1/333,(0..40°C) Measuring range from 0 to +40°C (measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit...
Room, outdoor and duct resistance thermometers Measuring range from -30 to +80°C Measuring insert 1x temperature sensor Pt100 in three-wire circuit Transmitter: without Protection class IP20 Suitabel for use in air conditioning...
Temperature measuring range: -50 … +350 °C / Metal mesh Measuring insert: 1x Pt 100 in two-wire circuit Installation length: 60 mm Cable length: 2500 mm Tolerance class: Class B (standard) Thermowell diameter: 6 mm...
UMO Dtrans T100 screw-in RTD temperature probe with programmable transmitter, M12 x 1 machine plug connection Measuring range from -50 to + 150 °C 1x Pt1000 in four-wire circuit Tolerance class: Class A Thermowell diameter: 6 mm Installation length: 50 mm Process...
JUMO Dtrans T100 screw-in RTD temperature probe without transmitter, M12 x 1 machine plug connection Measuring range from -50 to + 200 °C 1x Pt100 in four-wire circuit Tolerance class: Class B (standard) Thermowell diameter: 6 mm Installation length: 100 mm...
Screw-in resistance thermometer with connection head form J with stepped protection tube for air measurement Measuring range from -50 to +200 °C Single resistance thermometer 1x Pt 100 in two-wire circuit Tolerance class: Class B (standard) Thermowell diameter: 6...
Screw-in resistance thermometer with form J connection head With continuous protection tube Measuring range from -50 to +200 °C Single resistance thermometer 2x Pt 100 in two-wire circuit Tolerance class: Class B (standard) Thermowell...
Push-in resistance thermometer in water vapour-tight design, pressure-tight up to 5.0 bar Measuring range -70 to +200°C Connection cable: FEP 1 x Pt 100 in four-wire circuit Single resistance thermometer Tolerance class A according to DIN EN...
Push-in resistance thermometer in water vapour-tight design Measuring range -50 to +150°C Connection cable: PTFE 1x Pt 100 in four-wire circuit Single resistance thermometer Tolerance class A according to DIN EN 60 751 Thermowell...
Screw-in resistance thermometer with connecting cable and loose screw connection Metal braided connection cablesTemperature range from -50 to +400 °CWith loose screw connectionSingle resistance thermometer1x Pt 100 in two-wire circuitTolerance class according to DIN...
Screw-in resistance thermometer with connection cable and threaded protection tube Type: 902050/40-390-1003-1-8-25-111-11-2500/315,317 Metal braided connection cables Temperature range from -50 to +300 °C Single resistance thermometer 1x Pt 100 in two-wire circuit...
Screw-in resistance thermometer with connection cable, loose screw connection and stepped protection tube Silicone connecting cables Temperature range from -50 to +200 °C With loose screw connection Single resistance thermometer 1x Pt 100 in...
Screw-in resistance thermometer with connecting cable with fixed screw connection Silicone connecting cables Temperature range from -50 to +200 °C With fixed screw connection Single resistance thermometer 1x Pt 100 in three-wire circuit Tolerance class according to...
Pyrogen filterA pyrogen filter is a special type of filter used in water treatment to remove pyrogens from the water. Pyrogens are substances that can cause an immunological reaction in the body, in particular an increase in body temperature. As a rule, these are...
The NeoTec Slave 2/3/4G is designed for use in control and regulation systems with decentralised I/O nodes. It consists of CAN field bus components, all of which are designed for top-hat rail mounting and are graduated in snap-in widths of 22.5 mm. It is also possible...
Spare part measuring chamber holder without solenoid valve for Testomat 2000® and Titromat® Suitable for the following device types: Testomat 2000® Antox Testomat 2000® CN DUO Testomat 2000® DUO Testomat 2000® self-clean Testomat 2000® Titromat® M1 Titromat® M2...
The PRIUS piston metering pumps feature a spring return and combine efficiency and chemical resistance with a wide range of flow rates. They also offer a choice of power supply options including 240 VAC (single-phase) and 115 VAC (single-phase). The pump head is made...
The dosing pumps with motor in the PRIUS series were developed by EMEC to meet the highest requirements. The PRIUS D 50 Hz models ensure constant dosing and are equipped with a PTFE diaphragm. They also offer a choice of different power supply options including 380...
The dosing pumps with motor in the PRIUS series were developed by EMEC to meet the highest requirements. The PRIUS D 50 Hz models ensure constant dosing and are equipped with a PTFE diaphragm. They also offer a choice of different power supply options including 380...
The LOTUS MINI system is a device for the production, dosing and monitoring of chlorine dioxide for the disinfection of water and is available as a system with a capacity of 8 g/h (192 g/day) and as a system for up to 20 g/h (480 g/day). Chlorine dioxide is produced...
The LOTUS MINI system is a device for the production, dosing and monitoring of chlorine dioxide for the disinfection of water and is available as a system with a capacity of 8 g/h (192 g/day) and as a system for up to 20 g/h (480 g/day). Chlorine dioxide is produced...
LINI injection lances offer a number of advantages for your processes: Reduction of chemical deposits and crystalline formation at the injection point Housing made of high-quality materials such as PVDF (polyvinylidene fluoride), PP (polypropylene) or stainless steel...
The Testomat® 808 SIO02 is a device that was developed for measuring and monitoring deionised water (fully demineralised water) in medical facilities. The central importance of silicate monitoring Silicate measurement using...
The 100 ml bottle of original Testomat® indicator TH 2050 for the limit value 0.5- 5,0°dH only for Testomat® EVO TH. One packing unit contains 2 bottles á 100ml.
The emec service set for the VMS MF pump consists of the pump head, including sealing ring and a diaphragm, which is the same for all versions of the pump and is made of PTFE.Our service sets are available in the versions J and K. The only difference is the size of...
cleaneroo hand wash lotion (green)Ideal for hand hygiene Nourishing due to natural olive and sunflower oil No fragrances and dyes Vegan and animal-free No petrochemical additives Very productive
Manufacturer Part No. 3999960124 LAQUAtwin PH-33: The world’s first pocket-sized PH meter Your mobile laboratory – for use on site: Ideal for water quality testing in aquatic, drinking and process water and many other applications. HORIBA’s unique...
The Testomat 2000® Polymer process photometer is an online analyzer for monitoring the content of polyacrylate in the range fo 0 to 50 mg/l (ppm) (with a set product specific factor of 1.00) using the photometric analysis principle.Performance profile:...
The housing for holding the master or display unit as well as up to 10 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement...
Version 2: stock version: type 202560/20-888-000-310-000-23/000 ; part-no. 00480050 The unit is used for measuring/controlling the pH-value, the redox-voltage or the NH3-(ammonia)-concentration. The function can be switched directly on the unit. Depending on the...
Replacement color comparator without cuvette, for the TESTOVAL Chlorine DPD color comparison set for the concentration range 0.1-1 mg/l free and total chlorine. The individual values 0.1 mg/l, 0.2 mg/l, 0.3 mg/l, 0.5 mg/l, 0.75 mg/l and 1 mg/l can be read by optical...
500 ml bottle original Testomat® Indicator TM 2005 for limit value 0,05-0,50 mmol/l for measuring the minus m-value in water. mmol/l (resolution):0,05-0,50 (0,01)
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The solutions matching the tester in the form of the 25ml sachets or 70ml bottles find space in the...
The ORP sensor from the NeoTec Select Standard product range with Modbus module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
Refill pack: One set of reagents for TESTOVAL® PHOSPHATEST® (ORTHO-PHOSPHAT) for the rapid manual analysis of phosphate content in water in the concentration range 0-10 mg/l P2O5.1 set reagents (2xA, 1xB, 2xC)for approx. 180 analysesMeasuring time: approx. 5...
Testomat 2000® reagent FE 2005 B in 500 ml bottleMeasuring range: 0 – 1.0 [mg/l]Test substance: dissolved iron (II) and (III) For the analyser T2000® Fe, whose measuring ranges are as follows: Range I: 0 – 0.65 mg/l, resolution: 0.01...
Colour comparison kit for the concentration range 0.1-1 mg/l Cl2 (free and total) Individual values … 0.1 mg/l 0.2 mg/l 0.3 mg/l 0.5 mg/l 0.75 mg/l 1 mg/l … can be read by visual color comparison. In addition to the three reagents a...
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The 25ml sachet or 70ml bottle solutions matching the tester can be accommodated in the foam blank....
The bottles of original Testomat® LAB CL chlorine reagent Set T can be used immediately in the Testomat 2000® LAB CL without cumbersome filling and refilling.Contents:2 x 500 ml bottle AT reagent1 x 400 ml bottle B reagent
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The 25ml sachet or 70ml bottle solutions matching the tester can be accommodated in the foam blank....
The HyMo-Box “Kitchen Check” allows you to check the cleaning and disinfection performance of dishwashers. You receive reliable confirmation that the disinfection performance of the process used is sufficient. Wash your dishes as usual with the programme...
The 500 ml-bottle of original Titromat® TH 2500 Reagent B can be used immediately in the Titromat TH without cumbersome filling and refilling. resolution: 2,5 °dH Measuring range: Water hardness: 44.8 – 895 ppm CaC03 (resolution: 44,8 ppm...
Instrument for measuring the electrical conductivity of aqueous solutions in conjunction with two-electrode measuring cells. Designed as wall-mounted version.Operation at 230 V AC or 24 V DC possible2 potential-free relays – changeover switch for limit value...
DISINFECTION OF PROCESS, DRINKING AND ULTRAPURE WATERThe Neomeris UVprofessional Standard series consists of:Stainless steel reactor (1.4571 DIN EN 10217-7, outside electropolished) with conical external threads according to DIN 10241:2000, quartz immersion tube and...
Test kit for the determination of the base capacity up to pH 8,2; KB 8,2 of all natural and industrial water samples via titration with a liquid titration agent and a pipette with accurate mmol/l calibrations. Content: Complete with measuring tube, pipette with...
The 500 ml-bottles of original Titromat® TC 2010 Reagent A can be used immediately in the Titromat M1 without cumbersome filling and refilling. Measuring range: Carbonate hardness: 0.89 – 17.9 ppm CaC03 0.09 – 1.8 °f (resolution: 2...
This special service set is designed for the Testomat 2000® PO4. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head. The service set includes the following spare parts: 1 T2000...
Repair and Service Case Testomat® 808Case for regular maintenance of a Testomat® 808 and on-site service with lots of content. Content: 8 3.68×1.78 O-rings8 1.78×1.78 O-rings8 4.5×1.5 O-rings8 24×2 flat gaskets1 pump head4 500ml inserts...
Note: The system shown, consisting of two cabinets, is the fully equipped version of our system. The basic price is therefore supplemented by the selected options.The modular water treatment system was developed especially for the outpatient care sector. While...
Application: The Sonata device is an advanced and highly accurate ultrasonic water meter for home use. The Sonata’s dual pulse output provides high resolution consumption readings. Each of the two independent digital output channels can be configured to best...
Indicator/controller for digital sensors with Modbus protocolThe unit has 1 digital interface, 1 analogue temperature input and 1 binary input. The digital interface is suitable for connecting sensors that have a Modbus RS485 interface. If the connected sensor does...
The air purifier cleans the indoor air of viruses, bacteria, pollen, dust particles and suspended solids.Ideal for office, meeting room, reception, customer event and many other applications.Allergy sufferers can breathe freely and the risk of transmitting diseases...
KSS titration kit for simple monitoring of the content of cooling lubricants (KSS)by titration. Complete with all reagents and accessories. Concentration rangeand accuracy customized.
Range:0.00 to 14.00 pH0.00 to 20.00 mS/cm 0.00 to 10.00 ppt 0.0 to 50.0 °C / 32.0 to 122.0 °FResolution:0.01 pH0.01 mS/cm / 0.01 ppt 0.1 °C / 0.1 °FAccuracy (@25°C)0.05 pH2% FS (EC/TDS0.5 °C / ±1 °FTDS factor0.45 to 1.00 (CONV)Temperature CompensationAutomatic, with...
Service Set Testomat® Testomat® EVO TH / Testomat ECO®/Titromat® Content: 1 x gasket kit T2000 2 x sight glass windows 30×3 1 x flow regulator core, complete 3 x cylindrical protection plug with shoulder 5.3dx5 PE 1 x set of valves for the injection pump 1...
Replacement color comparator without cuvette, for rapid manual analysis of phosphate content in water in the concentration range 0-10 mg/l P2O5.The individual values 0.25 mg/l, 0.5 mg/l, 1 mg/l, 2.5 mg/l, 5 mg/l and 10 mg/l can be read by optical color comparison. By...
Manufacturer Part No. 3200689160 LAQUAtwin KA-11 : The world’s first pocket-sized potassium ion analyser. Your mobile laboratory – for use on site: Ideal for water quality testing in agriculture, food and many other applications. HORIBA’s unique...
High quality pH and redox electrode cleaning solution Our 250 ml and 500 ml bottles feature a special hygienic cap that protects the cleaning solution from contamination. To remove the required cleaning solution, simply squeeze the bottle and sufficient solution...
The practical analysis case contains a complete hand-held laboratory for testing the filling water of heating systems according to VDI guideline 2035. The conductivity meter and pH meter are IP65 certified, which means “dust-tight and protected against water...
Kit for the determination of free carbonic acid in water via drop titration. Description Complete with measuring tube, stopper and three reagents. Analyses: approx. 200 (at an average content of 100 mg/l CO2)
Refill pack: 8 ml bottle DUROVAL® Ks 4,3 indicator liquid For the determination of the acid capacity up to pH 4,3; Ks4,3 of all natural and industrial water samples via titration.
The 500 ml-bottles of original Testomat 2000® Reagenz CL 2250 C can be used immediately in the instrument without cumbersome filling and refilling. Measuring ranges: Total chlorine: 0,00-0,99 mg/l (Resolution: 0,01 mg/l) 1,0-0-2,5 mg/l (Resolution: 0,1 mg/l)...
Slow mode: With the exclusive SLOW MODE function of PRISMA dosing pumps, the stroke speed can be reduced from 100% to 1% during the priming cycle. This function facilitates the adaptation of the pump to the dosing medium and increases the reliability and deaeration of...
The Testomat® LAB CL and the Testomat® LAB CL-R are robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 – 5 mg/l. The instrument is suitable for controlling...
Complete colour comparison kit TESTOVAL Iron for quick manual analysis of the iron content in water in the concentration range 0 – 10 mg/l Fe.The individual values …0.25 mg/l0.5 mg/l1 mg/l2.5 mg/l5 mg/l10 mg/l … can be read by optical colour...
Dear customers, our handy pocket tester analysis case protects your handheld tester safely and also offers you space for the required calibration and buffer solutions. The 25ml sachet or 70ml bottle solutions matching the tester can be accommodated in the foam blank....
High-quality conductivity meter for conductivity monitoring Our innovative conductivity meter has been specially developed for monitoring conductivity in ultrapure water (demineralised water) and has a 4-20 mA signal output that enables easy integration into...
With our HyMo box “Temperature Check” you can check whether washing machines comply with the selected temperature ranges and thus document the proper condition of your appliances in everyday use. Load your washing machine or washing cycle machine as usual...
Typical areas of applicationindustrial and municipal, general water and waste water engineeringProcess measurements, electroplating, final inspections, neutralisation plantsdrinking and well water, boiler feed waterlightly contaminated waste waterDouble-chamber design...
TESTOVAL Copper Color Comparison Kit for rapid manual analysis of copper content in water in the concentration range 0-2 mg/l Cu.The individual values 0.1 mg/l, 0.25 mg/l, 0.5 mg/l, 1.0 mg/l, 1.5 mg/l and 2 mg/l can be read by optical color comparison. In addition to...
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even...
Cooler consists of Titanium steel 1.4571 for automatic sampling to 80°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm ...
The 500 ml-bottle of original Titromat® TC 2060 Reagent A can be used immediately in the Titromat® KH without cumbersome filling and refilling. resolution: 2 °dH Measuring range: Carbonate hardness: 89,5 – 2685 ppm (resolution: 8,9 ppm) 35,8...
The emec service set for the PRISMA pump consists of the pump head*, including sealing ring and a diaphragm, which is the same for all versions of the pump and is made of PTFE. Our service sets are available in the versions I, L, M and N. The only difference is...
Reagent A – 1 x 500 ml (CL2250A)Reagent B – 1 x 200 ml (CL2250B)(the reagent sets are designed for a uniform consumption of the reagents. Therefore, the capacities of the single reagent bottles are not equal)
Neomeris PPM150 Portable Photometer with USB interface The PPM 150 multiparameter handheld photometer for the determination of chemical water constituents is equipped with 9 LEDs in the wavelength range from 380 to 810 nm. The device has the following performance...
The bottles of Testomat 2000® Chlorine Reagent Set T 50 % can be used immediately in the Testomat 2000®® CLT, Testomat 2000® CLT Self Clean or Testomat 2000 THCL® without cumbersome filling and refilling. Content: 1 x 500 ml CL2250A 1 x 200 ml...
Refill pack for the determination of the base capacity up to pH 8.2. Analyses: approx. 100 (at an average base capacity of 1 mmol/l). Measuring time: approx. 2 minutes Measuring accuracy: 0.0.5 mmol/l
Booster pump for Testomat 2000®/ Testomat® EVO TH/Testomat® LAB/Titromat®. The pump installation is absolutely necessary for water input pressure below 0.3 bar.
The Testomat 2000® CLF process photometer is an online analyzer for monitoring the ontent of free chlorine (CLF) in the range of 0-2.5 mg / L (ppm).Performance profile: Analysis via automatic dosing of two reagents The analysis result is displayed after a...
Plug-in card for connecting Testomat 2000® to a protocol printer via the serial interface RS232, suitable for Testomat 2000® and Titromat® instruments. Technical Data for connecting a log printer or protocol converter (field bus, Ethernet,...
500 ml-bottle of original Testomat® 808 SIO2 Reagent A for monitoring the level of SiO2 in the water. The bottles of original Testomat® 808 SIO2 Reagent can be used immediately in the instrument without cumbersome filling and refilling. Measuring range: Silica...
LIMIT VALUE TEST KIT Liquid special indicator in dropper bottle for the monitoring of softened water, set for the limit values of 0.5 and 0.25 °dH (8,9 and 4,47 ppm). Description Complete with measuring tube and stopper Analyses:...
Replacement color comparator without cuvette, for the concentration range 0-20 mg/l SO32-.The individual values 0.5 mg/l, 1 mg/l, 2.5 mg/l, 5 mg/l, 10 mg/l and 20 mg/l can be read by optical color comparison. Only the color comparator for simple concentration...
The emec service set for the K-Plus pump consists of the pump head, including sealing ring and a diaphragm, which is the same for all versions of the pump and is made of PTFE. Our service sets are available in the versions I, L and M. The only difference is the...
Refill pack: 50 ml bottle DUROVAL® B titration solution for the determination of the water hardness in very soft or softened water samples via titration.
DISINFECTION OF PROCESS, DRINKING AND ULTRAPURE WATER The Neomeris UVprofessional Standard series consists of:Stainless steel reactor (1.4571 DIN EN 10217-7, externally electropolished), with conical external threads according to DIN 10241:2000 for single-lamp...
Color comparison kit for the rapid manual analysis of pH-value of water range pH 8 – 12. The individual values 8 mg/l 8.5 mg/l 9 mg/l 10 mg/l 11 mg/l 12 mg/l … can be read by visual color comparison. In addition to the reagents a color...
100 ml bottles original Testomat® indicator C15 for measuring carbonate hardness with Testomat® C-BOB. limit value:1,5 °dH carbonate hardness Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
Spare color comparator without cuvette, for rapid manual analysis of aluminum content in water in the concentration range 0-1.5 mg/l Al. The individual values can be read by optical color comparison. By diluting the water sample in a ratio of 1:10 with distilled...
Die Neomeris UV professional Pharma Serie wird in der pharmazeutischen- und Kosmetikindustrie verwendet.Unsere hochwertigen und in einer Vielzahl von renommierten Pharmabetrieben eingesetzten Anlagen bestehen aus: Edelstahlreaktor (1.4404 nach DIN EN 10537;...
Spare color comparator TESTOVAL Iron for the concentration range 0-1 mg/l Fe.The individual values 0.05 mg/l, 0.1 mg/l, 0.25 mg/l, 0.5 mg/l, 0.75 mg/l and 1 mg/l can be read by optical color comparison. By diluting the water sample 1:10 with distilled water, the...
The Ozone generator TOGC2 is based on the principle of „Silent Electrical Discharge” using oxygen or air as feedgas. The ozone production can be adjusted for a variable output: max. 10 g/h from oxygen and 4 g/h from dried air. The instrument is concepted for small...
The modular water treatment system was specially developed for the outpatient care sector. While the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the the quantities required in different outpatient centers, as well...